ETL Systems GNR-201-1U Genus 1U Redundant Chassis

The Genus chassis has a modular design which can house any combination of compatible modules within the unit. Supplying operators with a flexible and scalable solution, that reduces spare parts and rack space requirements. The 1U chassis houses up to 17 RF modules including Amplifiers, BUC/LNB Power Supplies, Frequency Converters, Matrices, RF over Fibre, Redundancy Switches and Test Loop Translators, which can be mixed. Providing a compact 1U system that is smaller in comparison with traditional 19” solutions, which could require 2U, 3U, 4U or more to achieve the same functionality. The Genus chassis provides a cost-efficient solution with field-replaceable components. The RF modules are field-serviceable and can be inserted whilst the shelf is in service, giving excellent levels of flexibility and resilience. With additional reliability from dual redundant hot-swap power supplies & field serviceable RF modules, HMI, CPU and optional user replaceable internal and external 10MHz reference source. General Specifications Capacity Up to 17 modules Note: Actual number dependent upon module type fitted Dimensions 1U high x 550mm deep x 19″ wide Weight Colour RAL9003 White (Semi-Matte) AC Power 85-264V AC (50/60Hz) AC Consumption 150W Max. consumption at steady state PSU Dual redundant & alarmed, Diode OR, Hot-swap RF Modules Single, field replaceable Reliability MTTR 20 minutes 15 minutes to retrieve spare part and 5 mins to replace. Applies to LRUs only and assumed in house stock. MTBF Chassis >250,000 CPU >250,000 Field serviceable components RF modules, CPU & HMI, [Optional] internal & external 10MHz reference source. Hot-swap components Dual redundant power supplies Redundancy Supporting 1+1, 2+1, 3+1, 3+2, 4+2 (with GNR redundancy modules) Control & Monitoring Local Control HMI, capacitive touchscreen Remote Control & Monitoring Ethernet via RJ45, 10BaseT/100BaseTx ETL TCP/IP protocol SNMPv3 & HTTPS Built-in Web Server Environmental Operating temperature 0 to 45˚C Location Indoor use only Storage temperature -20˚C to +75˚C Not Powered Humidity 20% – 90% non-condensing Relative Humidity Altitude Operational 10,000 ft AMSL (Above Mean Sea Level) Storage 30,000 ft AMSL (Above Mean Sea Level)

Compare
SKU: ETL Systems-GNR-201-1U Category: Tag:

Description

Description: The Genus chassis has a modular design which can house any combination of compatible modules within the unit. Supplying operators with a flexible and scalable solution, that reduces spare parts and rack space requirements. The 1U chassis houses up to 17 RF modules including Amplifiers, BUC/LNB Power Supplies, Frequency Converters, Matrices, RF over Fibre, Redundancy Switches and Test Loop Translators, which can be mixed. Providing a compact 1U system that is smaller in comparison with traditional 19” solutions, which could require 2U, 3U, 4U or more to achieve the same functionality. The Genus chassis provides a cost-efficient solution with field-replaceable components. The RF modules are field-serviceable and can be inserted whilst the shelf is in service, giving excellent levels of flexibility and resilience. With additional reliability from dual redundant hot-swap power supplies & field serviceable RF modules, HMI, CPU and optional user replaceable internal and external 10MHz reference source. General Specifications Capacity Up to 17 modules Note: Actual number dependent upon module type fitted Dimensions 1U high x 550mm deep x 19" wide Weight Colour RAL9003 White (Semi-Matte) AC Power 85-264V AC (50/60Hz) AC Consumption 150W Max. consumption at steady state PSU Dual redundant & alarmed, Diode OR, Hot-swap RF Modules Single, field replaceable Reliability MTTR 20 minutes 15 minutes to retrieve spare part and 5 mins to replace. Applies to LRUs only and assumed in house stock. MTBF Chassis >250,000 CPU >250,000 Field serviceable components RF modules, CPU & HMI, [Optional] internal & external 10MHz reference source. Hot-swap components Dual redundant power supplies Redundancy Supporting 1+1, 2+1, 3+1, 3+2, 4+2 (with GNR redundancy modules) Control & Monitoring Local Control HMI, capacitive touchscreen Remote Control & Monitoring Ethernet via RJ45, 10BaseT/100BaseTx ETL TCP/IP protocol SNMPv3 & HTTPS Built-in Web Server Environmental Operating temperature 0 to 45˚C Location Indoor use only Storage temperature -20˚C to +75˚C Not Powered Humidity 20% – 90% non-condensing Relative Humidity Altitude Operational 10,000 ft AMSL (Above Mean Sea Level) Storage 30,000 ft AMSL (Above Mean Sea Level)

The Genus chassis has a modular design which can house any combination of compatible modules within the unit. Supplying operators with a flexible and scalable solution, that reduces spare parts and rack space requirements. The 1U chassis houses up to 17 RF modules including Amplifiers, BUC/LNB Power Supplies, Frequency Converters, Matrices, RF over Fibre, Redundancy Switches and Test Loop Translators, which can be mixed. Providing a compact 1U system that is smaller in comparison with traditional 19” solutions, which could require 2U, 3U, 4U or more to achieve the same functionality. The Genus chassis provides a cost-efficient solution with field-replaceable components. The RF modules are field-serviceable and can be inserted whilst the shelf is in service, giving excellent levels of flexibility and resilience. With additional reliability from dual redundant hot-swap power supplies & field serviceable RF modules, HMI, CPU and optional user replaceable internal and external 10MHz reference source.

Downloads:

Original product page at Orbital Connect

Additional information

Weight 10 kg
Brand

ETL Systems

Weight (kg)

10.00

Reviews

There are no reviews yet.

Be the first to review “ETL Systems GNR-201-1U Genus 1U Redundant Chassis”

Your email address will not be published. Required fields are marked *

Select at least 2 products
to compare