Agilis ALB1292C6-80E-M ALB129 Series Compact 80W Ext. Ku-Band Block Up Converter
¥168,484.00
ALB129 Series Compact 80W Ku Band Block Up Converter This small and lightweight Block Upconverter (BUC) is ideal for mobile and satellite uplink applications. It boasts “Best in Class” efficiency and “lowest power con…
Description
ALB129 Series Compact 80W Ku Band Block Up Converter
This small and lightweight Block Upconverter (BUC) is ideal for mobile and satellite uplink applications. It boasts “Best in Class” efficiency and “lowest power consumption.” The unit operates on a broad AC power supply range of 96VAC to 264VAC. Its innovative and efficient thermal design contributes to making this BUC one of the smallest, most robust, reliable, and rugged devices capable of withstanding outdoor conditions in the industry.
A built-in redundancy feature eliminates the need for an external controller for 1:1 redundancy operation, simplifying cabling at the antenna and providing a very elegant solution. The BUC also offers extensive monitoring and control interfaces, including RS232, RS485, and Ethernet (supporting SNMP and HTTP).
Features
- Compact and lightweight design: Enhances portability and ease of installation.
- Standard and extended Ku-Band availability: Offers versatility for different frequency requirements.
- Forward power detection: Ensures accurate power monitoring.
- Intuitive monitoring and control: Accessible via RS232, RS485, and Ethernet interfaces (SNMP and HTTP).
- Automatic fault identification and alarm generation: Improves reliability and maintenance.
- Temperature compensation facility: Ensures stable performance across varying temperatures.
- Built-in redundancy: Provides seamless operation without external controllers.
- Built-in 10MHz reference with auto-detection: Ensures frequency stability.
- Wide operating temperature range: From -40ºC to +60ºC, suitable for extreme environments.
- RoHS Compliant: Environmentally friendly and meets safety standards.
- Waterproof: Suitable for outdoor installations and harsh weather conditions.
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity.
| RF Specifications | |
| Transmit Frequency |
13.75GHz – 14.5GHz (Ext Ku) |
| IF Frequency Range |
950MHz – 1700MHz (Ext Ku) |
| LO Frequency |
12.80GHz (Ext Ku) |
| Output Power | 49dBm (P1dB) |
| Spectral Re-growth | -30dBc @ Single carrier 3dB back-off from P1dB at 1.0 x symbol rate offset for QPSK or OQPSK |
| Third Order Intermod (two tone) | QPSK -25dBc @ two carrier 2MHz apart at 3dB back-off from P1dB |
| Small Signal Gain | 75dB Min |
| Gain Flatness Full Band | ±2dB |
| Gain Slope over 40MHz | ±1dB |
| Gain Variation over Temperature | ±2dB @ from -40°C to +60°C |
| Gain Control | 20dB in step of 0.5dB |
| O/P spurious | According to EN301428 |
| Phase Noise @ Offset | |
| 1KHz 10KHz 100KHz |
-73dBc/Hz -83dBc/Hz -93dBc/Hz |
| I/P VSWR | 1.5:1 |
| O/P VSWR | 1.2:1 with external Isolator |
| Noise Power Density Tx BD | -70dBW/4KHz |
| Rx BD | -142dBW/4KHz |
| Power Requirement | |
| Prime Power | 230VAC (range 96V to 264VAC) |
| Power Consumption | 550VA Typical at P1dB |
| Interfaces | |
| IF Input Interface | 50Ohms N-type Female |
| Output Interface | WR 75G |
| External Reference | |
| Frequency | 10MHz |
| Power | -5dBm to +5dBm |
| Internal reference | Built-in |
| External reference phase noise | |
| 1KHz 10KHz 100KHz |
-150dBc/Hz -155dBc/Hz -160dBc/Hz |
| Monitor And Control | |
| Monitor |
BUC temperature Status alarm Output power LED status indication |
| Control |
Attenuation RF output mute |
| Interface | RS232/RS485 & Ethernet (SNMP & HTTP) / WIFI (Optional) |
| Tx Redundancy | Built-in |
| Environmental | |
| Operating Temperature | -40°C to +60°C |
| Humidity | Up to 100%<br>Weather protection sealed to IP65 |
| Mechanical | |
| Size | 370L x 200W x 150H mm |
| Weight | 9.5kg |
| Color | White Powder Coat |
Datasheets / 技术资料下载
Additional information
| Weight | 9.5 kg |
|---|---|
| Dimensions | 20 × 37 × 15 cm |
| Brand | Agilis |
| Model | ALB1292C6-80E-M |
| Series | ALB 129 Series |
| Frequency Band | Ku-Band |
| Transmit Frequency | 13.75GHz – 14.5GHz (Ext Ku) |
| IF Frequency | 950MHz – 1700MHz (Ext Ku) |
| LO Frequency | 12.80GHz (Ext Ku) |
| Output Power | |
| Small Signal Gain | 75dB Min |
| Gain Flatness | ±2dB |
| Gain Variation | ±1dB; ±2dB @ from -40°C to +60°C |
| Gain Control | 20dB in step of 0.5dB |
| Intermodulation | -30dBc @ Single carrier 3dB back-off from P1dB at 1.0 x symbol rate offset for QPSK or OQPSK; QPSK -25dBc @ two carrier 2MHz apart at 3dB back-off from P1dB |
| Spurious | According to EN301428 |
| VSWR | 1.5:1; 1.2:1 with external Isolator |
| Noise Power Density | -70dBW/4KHz; -142dBW/4KHz |
| Prime Power | 230VAC (range 96V to 264VAC) |
| Power Consumption | 550VA Typical at P1dB |
| IF Input Interface | 1.5:1; 50Ohms N-type Female |
| RF Output Interface | According to EN301428; 1.2:1 with external Isolator; WR 75G |
| Reference | 10MHz; -5dBm to +5dBm; Built-in |
| Monitor | BUC temperature Status alarm Output power LED status indication |
| Control | Attenuation RF output mute |
| Communication Port | RS232/RS485 & Ethernet (SNMP & HTTP) / WIFI (Optional) |
| Redundancy | Built-In |
| Operating Temperature | -40°C to +60°C |
| Humidity | Up to 100%Weather protection sealed to IP65 |
| Dimensions | 370L x 200W x 150H mm |
| Weight | 9.50 kg |
| Colour | White Powder Coat |