Comtech CLNA-127 C-Band Low-Noise Amplifier Series

Compare

Description

ApplicationOur Low-Noise Amplifier (LNA) series includes LNAs and redundant LNA/LNB systems (C-, X-, Ku- or Ka- Q V  W Band). They meet or exceed system requirements for commercial  geosynchronous  satellites  worldwide.  Their  compact  design  and rugged construction make them ideal for transportable applications and severe environments. The LNAs have a comprehensive set of options to accommodate systems  ranging  from  Very  Small  Amplifier Terminal  (VSATs)  to  major  earth stations. The redundant LNA/LNB systems include primary and backup LNA(B)s and an automatic switching controller. In case of primary LNA/LNB failure, fast automatic switchover to the backup LNA/LNB minimizes downtime.

Technology

The amplifiers incorporate both HEMT devices for low-noise temperature performance and GaAs FET devices for low intermodulation. The units use surface mounted components for robotic manufacturing techniques, thereby insuring maximum product consistency and enhanced reliability. XLNA includes integrated filtering to address adjacent power issues peculiar to demanding X-Band terminals.

Reliability

The amplifier series utilizes proprietary circuitry and high-quality components to achieve an MTBF in excess of 160,000 hours. Each unit

is temperature cycled from -40 to 140oF (-40 to +60oC).

System Controller

The RC-11/1270 1:1/1:2 system controller (0 to 50 C operation, standard 19” 1RU chassis, nominally 16” deep) monitors the outdoor LNA/B system and provides the necessary 48V DC nominal redundant switch drive as well as selectable(13/18V) unit bias to operate multi-band LNBs. It has two independent internal power supplies allowing the customer to supply independent power sources (AC or optional 48V DC) for utmost reliability. It offers an easy-to-use front panel keyboard/display as well as full Ethernet capabilities (SNMP, Telnet, HTML, serial EIA-232/485) for integration with a customer network.

Subsystems

1+1 (one backup for one primary) and 1+2 (one backup for two primary) redundant LNA and LNB systems are available (refer to DST datasheet for available LNBs) complete with mounting plate, brackets and indoor Redundancy Controller/Power Supply (transmit reject filters, cables and other integration materials are offered as required).

LNA Specifications

Frequency

   
XLNA & REDXLNA 7.25 to 7.75 GHz
KLNA & REDKLNA 10.95 to 12.75 GHz

10.70 to 12.75 GHz

KaLNA & REDKLNA 19.7 to 21.2 GHz

19.2 to 20.2 GHz

17.8 to 19.3 GHz

20.2 to 21.2 GHz

Noise Temperature

 

CLNA 30, 35, 40, 45 K
XLNA 40, 45 K
KLNA 65, 70, 80, 85 K
KaLNA 120, 130, 150 K

Gain                                      50 dB or 60 dB All Bands, 70dB X-Band Only Overall Stability (Over Temp. & Frequency)

CLNA ± .75 dB from 3.625 to 4.2 GHz

± 1 dB from 3.4 to 4.2 GHz

0.40 dB p-p over 40 MHz

REDCLNA ± 1.5 dB over Full Band typical 0.50 dB p-p over 40 MHz typical
XLNA ± 1.5 dB over Full Band typical 0.50 dB p-p over 40 MHz typical
REDXLNA ± 2 dB over Full Band typical

 

  1 dB p-p over 40 MHz typical
KLNA ± 1.5 dB over Full Band

0.75 dB p-p over 40 MHz

REDKLNA ± 2 dB over Full Band typical

1 dB p-p over 40 MHz typical

KaLNA ± 2.0 dB over Full Band

1 dB p-p over 40 MHz

REDKaLNA ± 2.5 dB over Full Band typical

1.5 dB p-p over 40 MHz typical

 

Third Order Intercept +20 dBm (+30 dBm opt. for XLNA)
AM-PM Conversion 0.05°/dB @ -5 dBm (@ -10 dBm for KaLNA)
Linear Group Delay 0.01 ns/MHz (XLNA – ± .05 ns/MHz)
Parabolic Group Delay 0.001 ns/MHz2 (XLNA – ± .005 ns/MHz2)
Ripple 0.1 ns p-p (XLNA – ± 1 ns p-p)
Input/Output VSWR 1.25:1 Maximum (3.6 to 4.8 = 1.3:1) (1.5:1 Max Output VSWR for KaLNA)

Input Waveguide

CLNA & REDCLNA CPR229
XLNA & REDXLNA CPR112
KLNA & REDKLNA WR75
KaLNA & REDKaLNA WR42

 

Output Connector (C, X, Ku) Type N Standard, Optional SMA
Output Connector (Ka) SMA
Operating Temp. -40 to 140oF ( 40 to +60°C)
Input Power +12 to +24 VDC @ 120 mA
Power Connector Coaxial or PT06E-8-4S

 

System Diagrams

1:1 Redundant LNA System Block Diagram

 

1:2 Redundant LNA System Block Diagram

Typical System Noise Temperature Calculation

1:1 Redundant LNA System

Tsystem = TLNA + TSWITCH  + TOPTION 3 + TOPTION 1

1:2 Redundant LNA System

RF Input 1:LNA online signal path

Tsystem = TLNA + TSWITCH  + TOPTION 3 + TOPTION 1

RF Input 1:LNA 3 online signal path (LNA 1 Standby)

Tsystem = TLNA + 2*TSWITCH  + TW2 + TOPTION 3 + TOPTION 1 RF Input 2:LNA 2 online signal path

Tsystem = TLNA = TW1 +TSWITCH  + TOPTION 3 + TOPTION 1 RF Input 1:LNA 3 online signal path (LNA 2 Standby)

Tsystem = TLNA + 2*TSWITCH  + TW1 + TW2 + TOPTION 3 + TOPTION 1

Typical Noise Temperature in Kelvin at 23°C
Band (GHz) 3.62 – 4.205 3.4 – 4.2 7.9 – 8.4 10.7 – 12.75 Ka-Band
  WR-229 WR-229 WR-112 WR-75 WR-42
TSWITCH 1.50 1.50 3.00 5.00 12.00
TW1 1.50 1.50 4.00 4.00 7.00
TW2 1.50 1.50 2.5 4.00 7.00
TOPTION1 0.50 0.50 2.00 2.00 5.00
 

TOPTION3

 

2.40

 

7.00

 

28.0

 

15.00

 

NA

 

 

 

 

Reviews

There are no reviews yet.

Be the first to review “Comtech CLNA-127 C-Band Low-Noise Amplifier Series”

Your email address will not be published. Required fields are marked *

Select at least 2 products
to compare