Agilis ALB290FF7-60B ALB290 Series 60W Full C-Band VSAT Outdoor Block-Up Converter N Input (BUC)

¥42,617.00

Agilis ALB290FF7-60B ALB290 Series 60W Full C-Band VSAT Outdoor Block-Up Converter N Input (BUC) | Output Power: 60W | Band: C-Band

Compare
SKU: Agilis-ALB290FF7-60B Category: Tags: , , ,

Description

Agilis ALB290FF7-60B ALB290 Series 60W Full C-Band VSAT Outdoor Block-Up Converter N Input (BUC)

Agilis ALB 290 Series 60W C-Band BUC (Block-Up converter) is a highly cost effective outdoor RF transmitter for satellite communication. This small and lightweight BUC is ideal for mobile and satellite uplink applications. Designed to be mounted on the feed horn, the BUC has excellent efficiency. The unit works on a wide range DC power supply of 38V to 60V. The BUC is able to work up to 60ºC. Innovative and efficient thermal design makes this BUC one of the smallest, lightest and most reliable in the industry.

With redundancy-ready feature, the unit can be easily configured to work in 1:1 redundant mode.

Summary

This small and lightweight BUC is ideal for mobile and satellite uplink applications. Designed to be mounted on the feed horn, the BUC has excellent efficiency. The unit works on a wide range DC power supply of 38V to 60V. The BUC is able to work up to 60ºC. Innovative and efficient thermal design makes this BUC one of the smallest, lightest and most reliable in the industry.

With redundancy-ready feature, the unit can be easily configured to work in 1:1 redundant mode.

Features
• Compact and lightweight
• Feed mountable
• Wide operating temperature range -40ºC to +60ºC
• Wide input DC Voltage range 38V to 60V
• Standard remote monitor & control through RS485,
optional Ethernet (SNMP & HTTP)
• Excellent linearity
• Extremely reliable
• High power efficiency
• Available for all C-Band frequency ranges
• Excellent phase noise characteristics
• Low spurious
• Forward power detection facility
• Automatic fault identification & alarm generation
• Automatic temperature compensation feature
• Redundancy ready
• RoHS compliant
• Waterproof with IP65 standard
• LED indicator for BUC status
Frequency Band
FULL C
Tx : 5.850 to 6.725GHz
IF : 950 to 1825MHz
LO : 7675MHz / 4900MHZ

Reliability
Field proven under harsh environment conditions, Agilis ODUs can withstand temperature ranging from -40ºC to +60ºC with up to 100% humidity.
Quality Assurance
100% of all BUCs go through stringent quality checks in addition to well defined Electrical Stress Screening to ensure operation in harsh outdoor environments. The BUCs are also subjected to seal test for water ingress verification.
RF Specifications

Transmit Frequency

Full C

IF Frequency Range

FULL C
Tx : 5.850 to 6.725GHz
IF : 950 to 1825MHz
LO : 7675MHz / 4900MHZ

Output Power @ Psat

47.8dBm (60W)

Small Signal Gain

73dB (typical for 40W / 50W / 60W)

Gain Flatness

±2dB over the O/P frequency band

Gain Variation

±2dB over the operating temperature range

Gain Control

20dB in step of 0.5dB

Inter Modulation

-25dBc @ Relative to combine power of two carriers at 3dB total power backoff from Rated Output power

O/P spurious

According to EN301443

Phase Noise @ Offset

 

1 KHz

10 KHz

100 KHz

-73dBc/Hz max

-83dBc/Hz max

-93dBc/Hz max

I/P VSWR

2.0:1 max

O/P VSWR

1.5:1 max (with external isolator)

 
DC Power

Prime Power

48VDC (range 38 to 60VDC)

Power Consumption

312W @ 48VDC input (Typical for 60W)

Power Supply Interface

3 pins DC Connector (optional common input via IFL)

 
Interfaces

IF Input Interface

50Ohms N-type Female 

Output Interface

WR 137G / 50Ohms N-type Female (optional)

 
External Reference Requirement

Frequency

10MHz

Power

-5dBm to +5dBm

External reference phase noise requirement @ frequency offset

 

1KHz

10KHz

100KHz

-150dBc/Hz

-155dBc/Hz

-160dBc/Hz

 
Monitor & Control

Monitor

BUC Temperature
LO unlocked alarm
Status alarm
RF Output Power
LED status indicator

Control

Adjustable gain with 0.5dB step size RF output mute

Interface

RS232/RS485 (Standard) Ethernet (SNMP & HTTP) (Optional)

Tx Redundancy

1:1 Redundancy-ready (with external RCU)

 
Environmental
Operating Temperature -40ºC to +60ºC
  Optional (-40ºC to +70ºC for 40W)
Humidity Up to 100% Weather protection sealed to IP65
 
Mechanical

Size

235L x 175W x 90H mm / 9.3 x 6.9 x 3.5 in

Weight

3.9kg / 8.6lbs

Color

White Powder Coat

Additional information

Weight 3.9 kg
Dimensions 17.5 × 23.5 × 9 cm
Series

ALB290 Series

Brand

Agilis

Gain Flatness

±2dB over the O/P frequency band

Inter-Modulation

-25dBc @ Relative to combine power of two carriers at 3dB total power backoff from Rated Output power

IF Input Interface

50Ohms N-type Female

Frequency Band

10MHz

Monitor & Control

BUC TemperatureLO unlocked alarmStatus alarmRF Output PowerLED status indicator; Adjustable gain with 0.5dB step size RF output mute

Operating Temperature

-40ºC to +60ºC

Humidity

Up to 100% Weather protection sealed to IP65

Size

235L x 175W x 90H mm / 9.3 x 6.9 x 3.5 in

Weight

3.9kg / 8.6lbs

Small Signal Gain

73dB (typical for 40W / 50W / 60W)

Gain Variation

±2dB over the operating temperature range

I/P VSWR

2.0:1 max

O/P VSWR

1.5:1 max (with external isolator)

Prime Power

48VDC (range 38 to 60VDC)

Power Consumption

312W @ 48VDC input (Typical for 60W)

Output Interface

WR 137G / 50Ohms N-type Female (optional)

Power

-5dBm to +5dBm

Interface

RS232/RS485 (Standard) Ethernet (SNMP & HTTP) (Optional)

Tx Redundancy

1:1 Redundancy-ready (with external RCU)

Color

White Powder Coat

Transmit Frequency

Full C

IF Frequency Range

FULL CTx : 5.850 to 6.725GHzIF : 950 to 1825MHzLO : 7675MHz / 4900MHZ

Output Power

Gain Control

20dB in step of 0.5dB

Power Supply Interface

3 pins DC Connector (optional common input via IFL)

Spurious

According to EN301443

1KHz 10KHz 100KHz

-150dBc/Hz -155dBc/Hz -160dBc/Hz

1 KHz 10 KHz 100 KHz

-73dBc/Hz max -83dBc/Hz max -93dBc/Hz max

Reviews

There are no reviews yet.

Be the first to review “Agilis ALB290FF7-60B ALB290 Series 60W Full C-Band VSAT Outdoor Block-Up Converter N Input (BUC)”

Your email address will not be published. Required fields are marked *

Select at least 2 products
to compare